警告

当Exacticide尖端压紧橡胶或硅酮嵌缝时,可能会发生反压力。操作人员的这一动作将阻止空气和农药的正常流动。这一动作的结果可能会导致气罐以巨大的力量被吹走。如果发生这种情况,杀虫粉尘或颗粒会四处传播,造成混乱和危险。

超过40000的Exacticides在现场操作,这个问题发生了不到12次。请注意这一点将尖端放入可以密封空气流动的物体中。

作为一种预防措施,技术人员在精确灭虫棒的尖端附近放置了一个气压释放孔。我们建议你也这样做,你可能有现成的提示。使用1mm钻头。在钻头末端半英寸处钻一个孔。如果针尖被意外堵塞,这个孔会释放压力。

查看手册

PFC快速入门指南

祝贺您购买我们的PFC电动粉尘和细颗粒涂抹器!有了Exacticide,你的能力是无限的。随着您的使用范围的扩大,它将成为您解决所有虫害控制问题的首选工具,并使您只需使用其他行业标准方法完成服务所需时间的¼,就能高效地完成服务。本“快速入门指南”概述了最有效和最有效率的消灭害虫的方法。正确保养Exacticide将为您提供多年可靠的服务。1.智能充电器:将电池充电器从手提箱中取出,插入110v/220v电源插座。将电池放入充电座。然后你会看到充电器上有一盏红色的灯。如果你看到闪烁的红灯,电池可能带负电荷,需要10分钟才能变成纯红色。 If the blinking does not stop change wall outlets. The light will turn green when the charge is complete. 2. Loading Pesticide: Loading dust or fine granules: once you have filled the canister provided with the product of your choice, turn the Exacticide over and screw the canister on by twisting it into the Exacticide receiver lid. While tightening the canister in place, hold the mounded receiver lid with one hand while screwing the canister into place. Turn the Exacticide over into the upright position to begin an application. **Before squeezing the trigger set the volume control dial to the lowest setting and slowly turn the dial up until you hear the air pump come on. Then adjust to desired flow rate. (located to the left of the trigger) 3. Dust and Granule Usage: Do not mix dust, unless authorized by Technicide. Do not use large granules, only use granules with “FG” in the name or on the label. “FG” stands for fine granule. Do not use liquids in the Exacticide. *Warning* After extensive testing, we have found that Drione D does not flow very well in the Exacticide unit. To use Drione you will need to mix it 3-1 with Boric Acid. 3 parts being the Boric Acid. Do Not Use Eco Via WD by Rockwell Labs. Use CimeXa instead. 4. Maintenance - Clearing and Lubing the Impeller: Clear the impeller after each use by simply turning the Exacticide over into the same position that was used to load the canister. Squeeze the trigger while the tip is in a target void of your last targeted treatment area. While doing this, tap the side of the canister so all dust falls from the impeller. This procedure allows only air to pass through the manifold and clears the impeller. At the end of each day, repeat this procedure. Once the canister is removed, squirt dry Silicone lubricant into the small square hole in the semi-center of the receiver lid. One squirt is all that is needed. Run the Exacticide for a few seconds. Reinstall the canister and store in the case provided with the case stored upright. (Dry Silicone Lubricant, comes in an aerosol can sold on our website) Note: If you ever notice an excessive amount of dust building up on the inside of the unit stop using and contact Technicide immediately. 5. The Use of Extension Hoses: While using extension hoses, dust will build up on the walls of the hose. This build up can be managed by periodically turning the Exacticide over during application to allow only air to blow through. This method will help to reduce build up and periodic bursts of dust. Only use tips, wands and extensions manufactured by Technicide. Other devices may damage the tool and/or hinder performance. 6. Battery: To insure top performance, drain the battery all the way down for the first 3 times you use the battery. Thereafter draining all the way down to zero is not necessary. It is recommended that you do not store the battery connected to the unit. Each time you store the Exacticide unclip the battery and allow space so that the Exacticide terminals do not contact the battery. Caution: Extreme heat or cold may shorten the life of the battery. The battery life is expected to be 3-5 years. Store at room temp when not in use.

害虫控制设备

防虫动力喷粉机
EXACTICIDE
防虫饵枪延伸
TECH-REACH诱饵职业
快装鼠站
TECHNI-BAITER
害虫控制配件
配件